Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Urban Clim ; 36: 100803, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33614404

RESUMO

The implementation of confinement and physical distancing measures to restrict people's activities and transit in the midst of the COVID-19 pandemic allowed us to study how these measures affect the air quality in urban areas with high pollution rates, such as Santiago, Chile. A comparative study between the concentrations of PM10, PM2.5, NOx, CO, and O3 during the months of March to May 2020 and the corresponding concentrations during the same period in 2017-2019 is presented. A combination of surface measurements from the air quality monitoring network of the city, remote satellite measurements, and simulations of traffic activity and road transport emissions allowed us to quantify the change in the average concentrations of each pollutant. Average relative changes of traffic emissions (between 61% and 68%) implied statistically significant concentrations reductions of 54%, 13%, and 11% for NOx, CO, and PM2.5, respectively, during the pandemic period compared to historical period. In contrast, the average concentration of O3 increased by 63% during 2020 compared to 2017-2019. The nonlinear response observed in the pollution levels can be attributed to the changes in the vehicular emission patterns during the pandemic and to the role of other sources such as residential emissions or secondary PM.

2.
Air Qual Atmos Health ; 14(6): 925-933, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33558824

RESUMO

The sanitary measures implemented to control and prevent an increase in infections due to the COVID-19 pandemic have produced an improvement in the air quality of many urban areas around the world. We assessed air quality during the COVID-19 pandemic for particulate matter (PM2.5 and PM10), NO2 and O3 in in metropolitan area of Lima, Peru between pre-lockdown period (February 1 and March 15 of 2020), historical period (March 16 to April 30 2017-2019) and lockdown period (March 16 to April 30, 2020). The complete national lockdown that was implemented in Peru produced statistically significant reductions in the in-air pollutant (PM10 (-40% and -58%), PM2.5 (-31% and -43%) and NO2 (-46% and -48%)), as recorded by the by the ground-based air quality monitoring network throughout the metropolitan area, compared with the corresponding concentrations for the previous weeks and over the same period for 2017-2019. Analysis of the spatial Distribution of satellite data also show decreases in the concentrations of PM10, PM2.5 and NO2 as a result of the containment measures and suspension of activities implemented by the Peruvian government. The concentrations of O3 significantly increased (11% and 170%) as a result of the decrease in the concentration of NO2, confirming that the study area is a hydrocarbon-limited system, as previously reported. The results obtained contribute to the assessment by the regulatory agencies of the possible strategies of control and monitoring of air pollution in the study area. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11869-021-00990-3.

3.
Environ Sci Pollut Res Int ; 27(23): 29672-29680, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32500499

RESUMO

Oxidative stress is considered as one of the main mechanisms by which airborne particles produce adverse health effects. Several methods to estimate the oxidative potential (OP) of particulate matter (PM) have been proposed. Among them, the dithiothreitol (DTT) assay has gained popularity due to its simplicity and overall low implementation cost. Usually, the estimations of OPDTT are based on n-replicates of a set of samples and their associated standard deviation. However, interlaboratory comparisons of OPDTT can be difficult and lead to misinterpretations. This work presents an estimation of the total uncertainty for the OPDTT measurement of PM10 and PM2.5 samples collected in Santiago (Chile), based on recommendations by the Joint Committee for Guides in Metrology and Eurachem. The expanded uncertainty expressed as a percentage of the mass-normalized OPDTT measurements was 18.0% and 16.3% for PM10 and PM2.5 samples respectively. The dominating contributor to the total uncertainty was identified (i.e., DTT consumption rate, related to the regression and repeatability of experimental data), while the volumetric operations (i.e., pipettes) were also important. The results showed that, although the OP measured following the DTT assay has been successfully used to estimate the potential health impacts of airborne PM, uncertainty estimations must be considered before interpreting the results.


Assuntos
Poluentes Atmosféricos/análise , Material Particulado/análise , Animais , Chile , Ditiotreitol , Monitoramento Ambiental , Oxirredução , Estresse Oxidativo , Incerteza
4.
Environ Monit Assess ; 189(12): 635, 2017 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-29134287

RESUMO

The temporal and spatial trends in the variability of PM10 and PM2.5 from 2010 to 2015 in the metropolitan area of Lima-Callao, Peru, are studied and interpreted in this work. The mean annual concentrations of PM10 and PM2.5 have ranges (averages) of 133-45 µg m-3 (84 µg m-3) and 35-16 µg m-3 (26 µg m-3) for the monitoring sites under study. In general, the highest annual concentrations are observed in the eastern part of the city, which is a result of the pattern of persistent local winds entering from the coast in a south-southwest direction. Seasonal fluctuations in the particulate matter (PM) concentrations are observed; these can be explained by subsidence thermal inversion. There is also a daytime pattern that corresponds to the peak traffic of a total of 9 million trips a day. The PM2.5 value is approximately 40% of the PM10 value. This proportion can be explained by PM10 re-suspension due to weather conditions. The long-term trends based on the Theil-Sen estimator reveal decreasing PM10 concentrations on the order of -4.3 and -5.3% year-1 at two stations. For the other stations, no significant trend is observed. The metropolitan area of Lima-Callao is ranked 12th and 16th in terms of PM10 and PM2.5, respectively, out of 39 megacities. The annual World Health Organization thresholds and national air quality standards are exceeded. A large fraction of the Lima population is exposed to PM concentrations that exceed protection thresholds. Hence, the development of pollution control and reduction measures is paramount.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental , Material Particulado/análise , Poluição do Ar/análise , Cidades , Peru , Tempo (Meteorologia)
5.
Environ Int ; 82: 101-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25796098

RESUMO

A critical analysis of Chile's National Air Quality Information System (NAQIS) is presented, focusing on particulate matter (PM) measurement. This paper examines the complexity, availability and reliability of monitoring station information, the implementation of control systems, the quality assurance protocols of the monitoring station data and the reliability of the measurement systems in areas highly polluted by particulate matter. From information available on the NAQIS website, it is possible to confirm that the PM2.5 (PM10) data available on the site correspond to 30.8% (69.2%) of the total information available from the monitoring stations. There is a lack of information regarding the measurement systems used to quantify air pollutants, most of the available data registers contain gaps, almost all of the information is categorized as "preliminary information" and neither standard operating procedures (operational and validation) nor assurance audits or quality control of the measurements are reported. In contrast, events that cause saturation of the monitoring detectors located in northern and southern Chile have been observed using beta attenuation monitoring. In these cases, it can only be concluded that the PM content is equal to or greater than the saturation concentration registered by the monitors and that the air quality indexes obtained from these measurements are underestimated. This occurrence has been observed in 12 (20) public and private stations where PM2.5 (PM10) is measured. The shortcomings of the NAQIS data have important repercussions for the conclusions obtained from the data and for how the data are used. However, these issues represent opportunities for improving the system to widen its use, incorporate comparison protocols between equipment, install new stations and standardize the control system and quality assurance.


Assuntos
Poluentes Atmosféricos/análise , Material Particulado/análise , Chile , Monitoramento Ambiental/métodos , Substâncias Perigosas/análise , Reprodutibilidade dos Testes , Fatores de Tempo
6.
ScientificWorldJournal ; 2014: 794590, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24587753

RESUMO

Measurements of carbonaceous aerosols in South American cities are limited, and most existing data are of short term and limited to only a few locations. For 6 years (2002-2007), concentrations of fine particulate matter and organic and elemental carbon were measured continuously in the capital of Chile. The contribution of carbonaceous aerosols to the primary and secondary fractions was estimated at three different sampling sites and in the warm and cool seasons. The results demonstrate that there are significant differences in the levels in both the cold (March to August) and warm (September to February) seasons at all sites studied. The percent contribution of total carbonaceous aerosol fine particulate matter was greater in the cool season (53 ± 41%) than in the warm season (44 ± 18%). On average, the secondary organic carbon in the city corresponded to 29% of the total organic carbon. In cold periods, this proportion may reach an average of 38%. A comparison of the results with the air quality standards for fine particulate matter indicates that the total carbonaceous fraction alone exceeds the World Health Organization standard (10 µg/m(3)) and the United States Environmental Protection Agency standard (15 µg/m(3)) for fine particulate matter.


Assuntos
Poluição do Ar , Carbono/análise , Material Particulado/química , Chile , Cidades , Estações do Ano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...